Espar Heater "Maintenance Required" Message

Espar Heater "Maintenance Required" Message

Confirmed Issue:


The Espar Digi-Max D-1000 controller is displaying a "maintenance reqd" (maintenance required) message.



Affected Units:


Any Vandoit van with an Espar heater and Digi-Max D-1000 controller.


Explanation:

The "Maintenance Required" message is a default message that comes up after every 1,000 hours of furnace runtime, reminding you to perform routine maintenance on the heater--much like an oil change indicator on a vehicle dashboard.  It is not an indicator of an actual problem.

The timing of the "Maintenance Required" message can be adjusted using the instructions provided in this video: https://youtu.be/mkyhHQyhhD4

Idea
The Espar heater is set to a run time limit of 10 hours from the factory. This default runtime can be adjusted using the steps in this article: https://vandoit.zohodesk.com/portal/en/kb/articles/adjusting-the-espar-heater-run-time-limit

Resolution:


This video shows how to clear the message from the thermostat:  https://www.youtube.com/watch?v=mkyhHQyhhD4

This article walks you through routine maintenance steps:  https://vandoit.zohodesk.com/portal/en/kb/articles/espar-maintenance

The Vandoit Service Team can service your Espar if you prefer.  Just submit a ticket through the Vandoit Customer Support portal or email support@vandoit.com indicating that you would like to schedule a service appointment for your Espar.

If you have specific questions about maintaining your Espar heater, please submit a ticket through the Vandoit Customer Support portal or email support@vandoit.com.  Include photos of anything relevant to your inquiry.

    • Related Articles

    • Espar Airtronic Heater User's Manual

      Two Espar User's Manuals are attached,  Please note that most Vandoit vans have the B4 heater model installed. This video provides a helpful guide to performing a visual inspection of your Espar heater.  (Please note that the video shows a different ...
    • General Espar Maintenance

      Recommended Periodic Maintenance Remove the glow pin and inspect for carbon build up. Clean or replace. Remove the glow pin screen and inspect for carbon build up. Replace. Make sure the vent hole is not clogged. Inspect the ducting, the air intake ...
    • Espar Heater Not Working

      Confirmed Issue: The Espar heater stops working and/or the thermostat displays a "no flame detect" or "code 52" error message, on your Digi-Max D-1000. Affected Units: Any Vandoit van with an Eberspaecher Espar Airtronic B4 heater Issue Explanation: ...
    • General Knowledge: Espar Airtronic Heater

      Article Objective: The purpose of this article is to provide you with general knowledge on the Eberspaecher Espar B4 Airtronic Heater: Important details about how it is installed and how to operate it. Please see this article on how to conduct ...
    • User Manual: Espar Heater EasyStart Pro Thermostat

      Beginning in fall of 2022, some Vandoit vans with the Espar heater received an EasyStart Pro thermostat to control the Espar.  Please see the attached user manual for this thermostat.